Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Arq. bras. oftalmol ; 78(4): 252-254, July-Aug. 2015. ilus
Article in English | LILACS | ID: lil-759251

ABSTRACT

ABSTRACTPostoperative fungal endophthalmitis is a rare but devastating complication of cataract surgery. Vitrectomy and intravitreal amphotericin B injection as well as administration of systemic antifungal agents have been suggested as optimal treatments for fungal endophthalmitis. However, this therapy may fail to eliminate fungal species resistant to current antifungal agents. The saprophytic fungus Trichosporon asahii is frequently observed as a cause of endogenous endophthalmitis in immunosuppressed patients. We report a case of postoperative endophthalmitis caused by T. asahii, resistant to amphotericin B. To the best of our knowledge, this is the first report of T. asahii endophthalmitis successfully treated with intravitreal and systemic voriconazole, pars plana vitrectomy, and removal of the intraocular lens and entire lens capsule.


RESUMOEndoftalmite fúngica pós-operatória é uma complicação rara mas devastadora da cirurgia de catarata. A vitrectomia e injeção intravítrea de anfotericina B, bem como agentes fungicidas sistêmicos, têm sido sugeridos como tratamentos ideais para endoftalmite fúngica. No entanto, esta terapia pode falhar em erradicar as espécies de fungos resistentes aos agentes antifúngicos atuais. Uma dessas espécies de fungos é o fungo saprófita,Trichosporon asahii, que é frequentemente observada, como causa de endoftalmite endógena, em pacientes imunodeprimidos. Relatamos um caso de endoftalmite pós-operatória causada porT. asahii que é resistente a anfotericina B. Ao nosso conhecimento, este é o primeiro relato de endoftalmite porT. asahii tratado com sucesso com voriconazol intravítreo e sistêmico, vitrectomia viapars plana, e remoção da lente intraocular e saco capsular.


Subject(s)
Aged , Humans , Male , Antifungal Agents/administration & dosage , Cataract Extraction/adverse effects , Endophthalmitis/drug therapy , Eye Infections, Fungal/drug therapy , Trichosporonosis/drug therapy , Voriconazole/administration & dosage , Endophthalmitis/microbiology , Eye Infections, Fungal/microbiology , Intravitreal Injections , Trichosporon/classification , Trichosporon/isolation & purification
2.
Arq. bras. oftalmol ; 78(2): 115-117, Mar-Apr/2015. graf
Article in English | LILACS | ID: lil-744285

ABSTRACT

Bilateral acute iris transillumination (BAIT) is a relatively new clinical entity characterized by bilateral acute loss of iris pigment epithelium, iris transillumination, pigment dispersion in the anterior chamber, and sphincter paralysis. We report the case of a 30-year-old male who was initially diagnosed with acute iridocyclitis in a different clinic and treated with topical and systemic corticosteroids. He was referred to our clinic to seek another opinion because his symptoms did not improve. An ocular examination revealed bilateral pigment dispersion into the anterior chamber, diffuse iris transillumination, pigment dusting on the anterior lens capsule, atonic and distorted pupils, and increased intraocular pressure, suggesting a diagnosis of BAIT rather than iridocyclitis. Clinicians should be aware of the differential diagnosis of syndromes associated with pigment dispersion from iridocyclitis to avoid aggressive anti-inflammatory therapy and detailed investigation for uveitis.


A transiluminação de íris aguda bilateral (do inglês, bilateral acute iris transillumination, BAIT) é uma entidade clínica relativamente nova, caracterizada pela perda aguda bilateral do epitélio pigmentado da íris, transiluminação iriana, dispersão de pigmentos na câmara anterior, e paralisia do esfíncter pupilar. Nós relatamos o caso de um homem de 30 anos que foi diagnosticado com iridociclite aguda e tratado com corticosteroides tópicos e sistêmicos. Ele foi encaminhado ao nosso serviço para outra opinião, porque seus sintomas não melhoram com a terapia. Um exame oftalmológico revelou dispersão bilateral de pigmentos para a câmara anterior, transiluminação difusa de íris, pigmento difusa na cápsula anterior do cristalino, pupilas atônicas e distorcidas, e um aumento da pressão intraocular, o que sugere um diagnóstico de BAIT em vez de iridociclite. Os médicos devem estar cientes do diagnóstico diferencial das síndromes associadas à dispersão de pigmento com a iridociclite para evitar a terapia antiinflamatória agressiva e investigação detalhada para uveíte.


Subject(s)
Humans , Attitude of Health Personnel , Hospitals/standards , Personnel, Hospital , Quality Assurance, Health Care , Quality Improvement , Focus Groups , Georgia , Organizational Culture , Program Evaluation
5.
Arq. bras. oftalmol ; 77(6): 345-350, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-735807

ABSTRACT

Purpose: To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. Methods: A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed ophthalmic examination was performed in all cases following CCT measurements with OLCR, FD-OCT, and SC. The results were compared using an ANOVA test. Bland-Altman analysis was used to demonstrate agreement between methods. Intra-examiner repeatability was assessed by using intraclass correlation coefficients (ICCs). Results: Statistically significant differences were observed between the results of the CCT measurements obtained using the three different devices (p=0.009). Significant correlations were found between OLCR and FD-OCT (r=0.97; p<0.0001), FD-OCT and SC (r=0.91; p<0.0001), and OLCR and SC (r=0.95; p<0.0001). The 95% limits of agreement (LOA) obtained from Bland-Altman plots were from -7.2 μm to 28.7 μm for OLCR versus FD-OCT, from -19.2 μm to 30.4 μm for OLCR versus SC, and from -42.6 to 32.3 μm for FD-OCT versus SC. Intra-examiner repeatability was excellent for each method, with ICCs >0.98. Conclusion: Although the results of CCT measurements obtained from these three devices were highly correlated with one another and the mean differences between instruments were comparable with the reported diurnal CCT fluctuation, the measurements are not directly interchangeable in clinical practice because of the wide LOA values. .


Objetivo: Comparar os resultados de medições de espessura corneana central (CCT ) obtidos com reflectometria óptica de baixa coerência (OLCR), tomografia de coerência óptica de domínio Fourier (FD-OCT ), e uma câmera Scheimpflug (SC), combinada com topografia corneana de placido. Métodos: Um olho de cada de 25 indivíduos saudáveis foram incluídos neste estudo. Um exame oftalmológico detalhado foi realizado em todos os casos após as medidas de CCT com OLCR, FD-OCT, e SC. Os resultados foram comparados por meio do teste ANOVA. Análise de Bland-Altman foi utilizada para demonstrar concordância entre os métodos. A repetibilidade intra-examinador foi avaliada por meio de coeficientes de correlação intraclasse (ICCs). Resultados: Foram observadas diferenças estatisticamente significativas entre os resultados das medidas de CCT obtidas a partir de três dispositivos diferentes (p=0,009). Foram encontradas correlações significativas entre OLCR e FD-OCT (r=0,97, p<0,0001), FD-OCT e SC (r=0,91, p<0,0001), e OLCR e SC (r=0,95; p<0,0001). Os limites de 95% de confiança (LOA) obtidos a partir de gráficos de Bland-Altman foram de -7,2 a 28,7 μm para OLCR contra FD-OCT, de -19,2 a 30,4 μm para OLCR contra SC, e de -42,6 a 32,3 μm para FD-OCT contra SC. A repetibilidade intra-examinador foi excelente para cada método com ICCs>0,98. Conclusões: Apesar de os resultados das medições CCT obtidos a partir destes três dispositivos terem sido altamente correlacionados entre si e as diferenças médias entre os instrumentos serem comparáveis à flutuação relatado da CCT diurna, as medições não são diretamente intercambiáveis na prática clínica em razão da largura dos valores limites de confiança. .


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Young Adult , Cornea/anatomy & histology , Corneal Pachymetry/instrumentation , Corneal Pachymetry/methods , Corneal Topography/methods , Tomography, Optical Coherence/methods , Analysis of Variance , Anatomy, Cross-Sectional , Biometry/instrumentation , Biometry/methods , Corneal Topography/instrumentation , Fourier Analysis , Observer Variation , Photography/instrumentation , Reference Values , Reproducibility of Results , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL